Reader and interface versions
The SXK-A200QR is an integrated UHF RFID reader with an LED display. The A200Q and A200R variants have different interface combinations, including serial, Wiegand, Ethernet, 4G or PoE where specified.
UHF Reader
The SXK-A200QR is an integrated UHF RFID reader with an LED display. The A200Q and A200R variants have different interface combinations, including serial, Wiegand, Ethernet, 4G or PoE where specified.
Installers and system integrators matching vehicle credentials to an existing access controller.
The SXK-A200QR is an integrated UHF RFID reader with an LED display. The A200Q and A200R variants have different interface combinations, including serial, Wiegand, Ethernet, 4G or PoE where specified.
Use the model table in the datasheet to select the reader interface and input or output count. Send the exact variant code and the controller interface when you request a quote.
The A200Q and A200R variants have different interface combinations. Order by the variant table rather than assuming that Ethernet, 4G or PoE is fitted to every reader.
Read range depends on the tag, mounting position and surrounding conditions. Check the chosen tag at the actual vehicle approach before fixing the reader position.
Identify the connectors and terminal labels before planning the controller connection.
10/100 Mbps Ethernet supports selectable TCP server/client modes. The network LED is identified beside the LAN connector. The 4G version does not provide the RJ45 LAN port.
The DC jack is 5.5 × 2.5 mm, center positive and outer negative, for 9-24 V DC input. PoE versions use the specified 37-57 V DC supply. Confirm the ordered power version.
Two expansion-port positions are shown on the reader. Confirm their fitted functions and accessories with the exact model configuration.
The illustrated connector has two relay contact pairs.
| Pin | Signal | Function |
|---|---|---|
| 1-2 | NX1 / CM1 | Relay 1 contact pair |
| 3-4 | NX2 / CM2 | Relay 2 contact pair |
Use the switch signal of the selected relay. Available output counts follow the ordered version.
Connection labels for the access controller or supported serial interface.
| Pin | Signal | Function |
|---|---|---|
| 1 | WG0 | Wiegand data 0 |
| 2 | WG1 | Wiegand data 1 |
| 3 | GND | Ground |
| 4 | 485A | RS485 A |
| 5 | 485B | RS485 B |
Wiegand supports 26/34 formats. Match the communication interface to the selected reader version.
Trigger inputs, serial data and terminal-block power input.
| Pin | Signal | Function |
|---|---|---|
| 1 | IN1 | Trigger input 1 |
| 2 | IN2 | Trigger input 2 |
| 3 | RXD | RS232 receive data |
| 4 | TXD | RS232 transmit data |
| 5 | GND | Ground |
| 6 | +12 | Power input: 9-24 V DC |
The supplied RS232 specification lists 115200 bit/s as default, with 9600, 19200, 38400, 56000 and 57600 bit/s options.
The diagram shows the illustrated connection layout. Fitted interfaces and input/output counts depend on the ordered model.
Compare interface versionsTechnical reference: interface diagram, p. 3; interface specifications, p. 4.
| Model | RS232 | Wiegand | RS485 | Ethernet | 4G | PoE | Inputs | Outputs |
|---|---|---|---|---|---|---|---|---|
| SXK-A200Q-DR-1N1A | — | √ | √ | — | — | — | 1 | 1 |
| SXK-A200Q-CDNR-2N2A | √ | √ | √ | √ | — | — | 2 | 2 |
| SXK-A200Q-CDNPR-2N2A | √ | √ | √ | √ | — | √ | 2 | 2 |
| SXK-A200Q-CDGR-2N2A | √ | √ | √ | — | √ | — | 2 | 2 |
| SXK-A200R-CDNR-2N2A | √ | √ | √ | √ | — | — | 2 | 2 |
| SXK-A200R-CDNPR-2N2A | √ | √ | √ | √ | — | √ | 2 | 2 |
| SXK-A200R-CDGR-2N2A | √ | √ | √ | — | √ | — | 2 | 2 |
Model selection reference from the supplied datasheet. Confirm the exact version and installation drawing with the order.
Pair the SXK-A200QR reader with SXK-TG11 windshield tags for vehicle identification.
The SXK-TG11 is a self-adhesive UHF RFID tag for vehicle windshields. It uses an Alien H3 chip, an aluminum antenna and EPC Class 1 Gen 2 communication in the 860–960 MHz band.
The tag uses an aluminum antenna and a self-adhesive windshield format. Check the windshield position with the selected UHF reader before applying tags across a vehicle fleet.
Confirm the reader protocol and the credentials the controller expects. Include any logo, tag-size or identifier requirements in the order brief.
These values apply to the tag; reader specifications are listed separately below.
A reader specification does not automatically apply to its paired tag. Read range and identification behaviour depend on the selected combination.
Functional sequence for configuration planning. Use the approved project drawing for physical wiring and installation.
Send these details with your enquiry so we can review the equipment and configuration.
Details for equipment review and installation planning.
Technical reference: datasheet p. 4.
Review the dimensions and installation clearances. Select a drawing to enlarge it.
Match the equipment to the site, the users and the access workflow.
Confirm the installed controller and credential type before replacing a reader. Test the actual approach and mounting position.
Vehicle identification lane illustration; reader and tag models vary by project.Define the vehicle credential batch and access permissions. Check the reader and tag pairing before deployment.
Project planning exampleOrder by the complete reader or tag version. Record the interface, power arrangement and required accessories.
Project planning exampleProduct documents for your technical review.
Product functions, specifications and configuration scope.
Specifications for the matching SXK-TG11 UHF windshield tag.
Questions about selection, integration and installation.
The SXK-A200QR is an integrated UHF RFID reader with an LED display. The A200Q and A200R variants have different interface combinations, including serial, Wiegand, Ethernet, 4G or PoE where specified.
Pair the SXK-A200QR reader with SXK-TG11 windshield tags for vehicle identification. Reader and tag specifications are listed separately on this page.
Send the credential technology and existing reader or controller details. Compatibility must be checked against the exact version.
Read performance depends on the credential, mounting position and surrounding conditions. Test the proposed combination at the site.
Specify the exact model or variant, quantity, interface, supply and mounting requirements. For tags, include the matching reader and credential requirements.
Use the model table in the datasheet to select the reader interface and input or output count. Send the exact variant code and the controller interface when you request a quote.
We provide remote video technical guidance, installation videos, wiring diagrams and installation instructions. For large projects, an engineer can provide on-site technical guidance.
Send the model, quantity and installation requirements. Include your layout or controller details where relevant.
Replies within 2 hours during Beijing business hours.