SXK-PT02

Parking Intercom Terminal

The SXK-PT02 combines a call button, camera and speaker in a freestanding steel column. Drivers can call an operator for help with entry, payment or exit.

12V DCOperating supply

Features & configuration.

Parking installers and operators planning driver assistance and control-room calls.

Driver call point at the lane

The SXK-PT02 combines a call button, camera and speaker in a freestanding steel column. Drivers can call an operator for help with entry, payment or exit.

Connect voice, video and gate controls

The terminal supports SIP 2.0 and ONVIF and has open and close relay outputs. Tell us which intercom platform and gate controller will be used.

A driver call point

The freestanding column puts the call button, camera and speaker beside the lane. Position it where the driver can reach the button from the stopping point.

Review voice, video and gate control

The terminal supports SIP 2.0 and ONVIF with open and close relay outputs. Confirm the intercom platform and controller before connecting the lane.

How it fits your project.

Network options, cameras and gate-control paths follow the ordered terminal, station and platform configuration.

  1. Place a lane call
  2. Connect voice and video
  3. Review the driver request
  4. Apply the authorised gate command

Functional sequence for configuration planning. Use the approved project drawing for physical wiring and installation.

Confirm before installation.

Send these details with your enquiry so we can review the equipment and configuration.

  • Number and position of lane terminals
  • Intercom platform and call routing
  • Network and power arrangement
  • Gate-command interface and operator permissions

Specs.

Details for equipment review and installation planning.

Device & construction

Model
SXK-PT02
Product type
Freestanding video intercom terminal for parking lanes
Overall dimensions
1250 × 150 × 90 mm; height × width × depth
Body material
Galvanized steel sheet
Installation form
Freestanding column with fixing base

Operation & performance

Processor
Embedded system on chip processor
Operating system
Embedded Linux
Camera sensor
2 megapixel CMOS
Camera assistance
Wide angle camera with illumination module
Video compression
H.264 at 25 frames per second
Audio processing
Noise reduction, echo cancellation and feedback suppression
Audio codec
G.711
Base footprint
230 × 170 mm
Front panel
Brushed aluminum alloy

Interfaces & integration

Audio input
Built-in high sensitivity omnidirectional microphone
Audio output
Built-in 5W speaker
Call and video integration
SIP 2.0 and ONVIF
Network interface
10/100 Mbps autosensing Ethernet
Network configurations
Wired Ethernet, Wi-Fi and 4G; specify the required configuration
Gate relay interfaces
One opening relay path and one closing relay path
Input interfaces
3 input channels for sensor / I/O integration

Power & environment

Operating supply
12V DC
Power consumption
≤10W
Operating temperature
-30 to +75 °C

Technical reference: datasheet p. 2, datasheet p. 4.

Applications.

Match the equipment to the site, the users and the access workflow.

Entry assistance

Place the driver terminal beside the stopping position. Define call routing and the operator response workflow.

Parking entrance assistance illustration; intercom and control equipment vary by project.

Payment and exit assistance

Connect the help point to the parking operation. Confirm how an authorised operator handles release requests.

Project planning example

Control-room operation

Plan the operator station, network and connected lane terminals. Set user permissions for gate commands.

Project planning example

Downloads.

Product documents for your technical review.

Before you order.

Questions about selection, integration and installation.

What is the SXK-PT02 Parking Intercom Terminal used for?+

The SXK-PT02 combines a call button, camera and speaker in a freestanding steel column. Drivers can call an operator for help with entry, payment or exit.

Can it use our intercom platform?+

Send the platform and network requirements. Confirm protocol compatibility and call routing for the exact terminal and station configuration.

Can an operator control the barrier?+

Review the supported relay or platform command path with the gate controller. Confirm the authorised actions for the operator.

What should be tested before handover?+

Test each call point, voice and video connection, call routing and permitted gate actions. Check the driver reach and operator position.

What should I confirm before ordering SXK-PT02?+

The terminal supports SIP 2.0 and ONVIF and has open and close relay outputs. Tell us which intercom platform and gate controller will be used.

How can you help with installation?+

We provide remote video technical guidance, installation videos, wiring diagrams and installation instructions. For large projects, an engineer can provide on-site technical guidance.

Related equipment.

Let’s review your configuration.

Send the model, quantity and installation requirements. Include your layout or controller details where relevant.

Replies within 2 hours during Beijing business hours.