SXK-COB02

Push Button Switch

The SXK-COB02 provides separate wired OPEN and CLOSE push buttons. Its enclosure has cable-entry knockouts at the side and bottom.

Features & configuration.

Installers and equipment buyers matching local controls and backup equipment to barrier cabinets.

Open and close controls

The SXK-COB02 provides separate wired OPEN and CLOSE push buttons. Its enclosure has cable-entry knockouts at the side and bottom.

Connect to the barrier controller

Use the shared SXK-COB02/COB03 datasheet to check the terminals and controller inputs. Choose the SXK-COB03 if the local station needs a separate rotary STOP control.

Two local commands

The station provides separate OPEN and CLOSE buttons. Check the controller command terminals and cable-entry arrangement before installation.

Choose the required control station

Use SXK-COB03 where the local station needs a separate rotary STOP control. The shared datasheet compares the two enclosures and command layouts.

How it fits your project.

Check the delivered module and controller diagrams before connection. Follow the specified isolation and commissioning procedure.

  1. Confirm the controller interface
  2. Connect the specified module
  3. Set the intended operation
  4. Test the complete barrier

Functional sequence for configuration planning. Use the approved project drawing for physical wiring and installation.

Confirm before installation.

Send these details with your enquiry so we can review the equipment and configuration.

  • Barrier and controller model
  • Supply and contact requirements
  • Cabinet space and cable route
  • Required operation and commissioning test

Specs.

Details for equipment review and installation planning.

Device & construction

Model
SXK-COB02
Product type
Enclosed manual control switch station
Enclosure material
ABS + PC
Contact material
Silver contacts
Enclosure sealing
Perimeter sealing strip and screw-fastened cover
Installation
Surface-mounted control station
Finish shown
Dark front cover with light enclosure base
Enclosure dimensions
130 × 65 × 70 mm

Operation & performance

Contact functions
NO, NC, COM
Utilization category markings
AC-15 / DC-13
Terminal connection
Screw terminals on the contact blocks
Cable entry
Side and bottom knockouts

Power & environment

Enclosure protection
IP65, with enclosure sealed and cable entries correctly finished
Conventional thermal current Ith
10 A
Rated insulation voltage Ui
415 V
Power requirement
Passive switch contacts; connection follows controller input requirements

Technical reference: datasheet p. 1, datasheet p. 2.

Wiring diagrams.

Review the supplied connection drawings. Select a drawing to enlarge the labels and terminals.

SXK-COB02 / SXK-COB03 controller connection examples
Source document, p. 3

Applications.

Match the equipment to the site, the users and the access workflow.

Local operator position

Define the commands an operator needs and the cable route. Check terminals and the compatible controller inputs.

Controlled parking entrance illustration; control and power components follow the project design.

Cabinet integration

Review supply, mounting space and the required connection. Keep the installed module clear of moving components.

Project planning example

Replacement equipment

Identify the existing controller and wiring before ordering. Verify the complete system after replacing the component.

Project planning example

Downloads.

Product documents for your technical review.

Before you order.

Questions about selection, integration and installation.

What is the SXK-COB02 Push Button Switch used for?+

The SXK-COB02 provides separate wired OPEN and CLOSE push buttons. Its enclosure has cable-entry knockouts at the side and bottom.

Will it work with my current barrier?+

Send the barrier controller and wiring details. The module must match the required electrical and control interface.

What is included with the component?+

Confirm the module, fittings and wiring scope with the order. Other lane equipment remains separately specified.

What should be tested after connection?+

Check the intended command or backup function with the actual controller. Record the final settings and complete the system handover checks.

What should I confirm before ordering SXK-COB02?+

Use the shared SXK-COB02/COB03 datasheet to check the terminals and controller inputs. Choose the SXK-COB03 if the local station needs a separate rotary STOP control.

How can you help with installation?+

We provide remote video technical guidance, installation videos, wiring diagrams and installation instructions. For large projects, an engineer can provide on-site technical guidance.

Related equipment.

Let’s review your configuration.

Send the model, quantity and installation requirements. Include your layout or controller details where relevant.

Replies within 2 hours during Beijing business hours.

Chat on WhatsApp